Declaration of Conformity and Certification of Medical Devices: What You Need to Know

February 27, 2026
Medical devices are instruments, apparatus, tools and materials used for prevention, diagnosis, treatment and rehabilitation. They range from complex systems such as X-ray machines and ventilators to simple items such as tourniquets and bandages.
To bring such devices to the Russian market, their safety, quality and compliance with requirements must be confirmed. This is done through certification or a declaration of conformity.
A certificate of conformity is issued by an accredited body. It is based on laboratory testing followed by an independent assessment.

A declaration of conformity is drawn up by the applicant. The applicant relies on test results and is personally responsible for the accuracy of the information.

The difference lies in the level of external control. Certification involves more independent verification. With a declaration, the manufacturer bears greater responsibility.

The practical point is simple. Certification helps when trust, tenders and third-party confirmation matter. A declaration is suitable when you need to complete the paperwork faster and reduce administrative costs while staying within the requirements.

Main types of medical devices and their classification

Medical devices are classified by the potential risk of their use. There are four classes, from simple to critical.

  • Class 1 — low risk. Usually non-invasive devices, medical furniture and simple instruments.
  • Class 2a — medium risk. Devices for short-term procedures and some diagnostic instruments.
  • Class 2b — elevated risk. Equipment for long-term exposure, life support systems and radiation-emitting devices.
  • Class 3 — high risk. Implants, devices that come into contact with blood or vital systems, and deeply invasive solutions.
The class is determined by intended use, duration of contact and degree of invasiveness. That is why a catheter will almost always carry a higher risk than a thermometer. The higher the class, the stricter the control and the more requirements must be met before the device is placed on the market.

Legislative framework and regulatory documents

The medical device market in Russia is regulated by Federal Law No. 323-FZ. It establishes the basic rule: products need state registration to be allowed on the market.

Safety requirements are set by Russian and EAEU regulations and applicable standards. Manufacturing and quality control rely on GOST standards, as well as GOST ISO 13485-2017, the standard for manufacturers' quality management systems (QMS).

Responsibilities are divided as follows:

  • Roszdravnadzor handles registration and oversees the circulation and safety of medical devices.
  • Rosaccreditation is responsible for accrediting certification bodies and supervising them.
  • Specialized agencies, such as Rospotrebnadzor, are involved where sanitary requirements are concerned.
Recent changes must also be taken into account. Decree No. 2425 of December 23, 2021 established that mandatory certification does not apply to medical devices as a general requirement. If a device has a registration certificate, a separate mandatory certificate is generally not required, except in cases set out in specific lists or requirements for components.

Decree No. 135 of February 9, 2022 requires a QMS under GOST ISO 13485-2017 for sterile class 2a devices and for all class 2b and 3 devices. In other words, there is now more focus on quality processes and less on paperwork for its own sake.

Procedure for obtaining a declaration of conformity for medical devices

A declaration of conformity follows a relatively simple procedure once testing has been completed and the document package has been assembled.

First, the applicant prepares a basic set of documents: the technical documentation for the device, test reports (electrical safety, biocompatibility and other required tests) and information about the manufacturer. For some items, especially medical equipment, a Roszdravnadzor registration certificate will also be required.

Next, an application is submitted through a certification body or the Rosaccreditation online service. The application must state the exact name of the device, its risk class and the applicant's details (INN/OGRN). After verification, the declaration is registered and then entered into the register.

Under the regulations, registration takes up to 3 working days after the documents are received. In practice, it often takes about a week if there are no comments. The result is a registered declaration with a number confirming compliance with the requirements.

The minimum package usually includes the company's incorporation documents, a description of the device (technical specifications or a reference to a GOST standard) and test reports. For imports, a contract with the manufacturer and documents for the authorized representative in Russia are added.

Declaration specifics for different types of devices

  • Medical equipment. Diagnostic instruments, life support equipment and X-ray systems are medical devices. They require registration with Roszdravnadzor to be placed on the Russian market. The key document for placing a medical device on the Russian market is the Roszdravnadzor registration certificate. A declaration of conformity or a certificate is issued in addition, where specific regulatory requirements call for it or on a voluntary basis. This is followed by test reports (electrical safety, EMC, biosafety) and submission of the documents to a certification body.
  • Medical goods and consumables. These include dressings, syringes, needles, sterilization materials and furniture. Many of these items are risk class 1, and a declaration is usually sufficient. Testing is usually simpler: strength, design safety and the absence of elements that could cause injury. Sanitary and epidemiological requirements nevertheless remain mandatory.
  • Software for medical purposes. Medical software (image visualization, decision support algorithms) is treated as a medical device. It is assigned to one of the four risk classes. State registration is required for lawful use; the procedure and its scope depend on the software's potential risk class. After state registration, a declaration of conformity may be issued if the relevant requirements apply. A separate certificate is usually not needed, but a registration certificate or declaration is mandatory for import and for operating on the Russian market.
Problems most often arise from an incomplete package: missing test reports, errors in the application or a missing risk class. The second most common issue is that mandatory tests have not been carried out. Timing is a separate risk. If you are late with a renewal or submit the declaration too close to import, you face a delayed shipment and sometimes a fine, because import without a valid declaration is not permitted.

To avoid disruptions, check the requirements in advance, complete all tests, gather the documents and fill in the application strictly according to the form.

Certification of medical devices: what it is and why it is needed

Certification confirms that a device meets the requirements of regulations and standards. The procedure is carried out by an accredited body. Certification is based on laboratory testing, and a certificate of conformity is issued at the end.

How it differs from a declaration

With a declaration, the applicant bears responsibility. With certification, there is an independent assessment by the certification body, with laboratory test reports as the mandatory basis.

Is it mandatory

Since 2021 (Decree No. 2425), medical devices generally do not require mandatory certification. State registration is usually sufficient, and sometimes a declaration is needed. A mandatory certificate for the medical device itself is generally not required.

Why do it voluntarily

A certificate adds credibility. It helps in negotiations with clinics and in procurement where third-party confirmation is expected. ISO 13485 QMS certification also makes it easier to pass audits, win large contracts and prepare for export.

When a certificate is unavoidable

If a product falls under mandatory certification under specific lists or regulations for particular components, a certificate becomes a condition for selling it legally.

Certification of medical equipment in Russia

Medical equipment more often requires in-depth testing. Electrical safety, electromagnetic compatibility and biosafety of materials are checked. For radiation-emitting equipment, radiation safety is added. The certificate confirms that the device has passed these checks.

GOST R, EAEU, ISO: why they matter

GOST R (or EAEU and technical regulation requirements) ensures basic safety under national rules. An ISO 13485 certificate shows that the manufacturer has a QMS in place: development, production and control processes are documented, managed and verifiable. This simplifies audits and reduces questions from inspectors.

Certification examples

CT scanners, operating tables, ECG machines and ventilators may be certified in Russia, on a mandatory or voluntary basis depending on the requirements and the purpose of confirming conformity. A certificate helps meet requirements faster when bringing a product to market. It also improves the chances of taking part in public procurement and makes it easier to get equipment accepted by hospitals.

State registration of medical devices with Roszdravnadzor

A registration certificate is a Roszdravnadzor document. It confirms that the device has been entered into the state register. Without a registration certificate, medical devices cannot be lawfully manufactured, imported or used in Russia.

How registration works

The manufacturer or authorized representative submits an application with a package of documents: a description of the device, information about the manufacturer, test results and other mandatory materials. Roszdravnadzor first checks that the package is complete, then sends the materials for expert review. Based on the results, it makes a decision. If the result is positive, a registration certificate is issued and an entry appears in the public register.

The timeline for state registration depends on the risk class and the scope of the expert review and can take several months.

Post-issuance control

Roszdravnadzor may request clarifications or additional tests. For imports, customs is involved, and sanitary checks are sometimes required. After registration, inspections and post-registration surveillance are possible. In the event of violations, measures may be tightened: the registration certificate may be suspended or the registration cancelled.

Quality management system (QMS) requirements for manufacturers

A QMS shows that the quality of medical devices is controlled not just at the end of production but at every stage. Roszdravnadzor assesses how processes are organized. An ISO 13485 certificate confirms that a quality management system is in place and makes it easier to pass inspections and audits by regulators and customers.

What GOST ISO 13485-2017 requires

The standard sets a framework for quality management: documentation, controlled development, production control, process validation and post-market monitoring. The mandatory set includes incoming inspection of materials, change management, internal audits, release of products only after inspection, handling of nonconformities and risk management.

When a QMS is mandatory

Under Decree No. 135 of February 9, 2022, a QMS under GOST ISO 13485-2017 is required for manufacturers of sterile class 2a devices and for all class 2b and 3 devices. During supervision, staff training, quality records and compliance with production procedures are also examined.

Implementing and maintaining a QMS

Implementing a QMS starts with a management decision and the appointment of responsible persons. Next, a quality policy, a quality manual and a set of procedures are drawn up. Rules for documents, development, purchasing, production and feedback are established. Staff are trained so that everyone understands their role.

QMS control and audit

Audits are both internal and external (during QMS certification). Internal audits find weak points before inspectors arrive. External audits confirm compliance with the standard. The results are reviewed at management level and corrective actions are launched. A QMS is a continuous process, from planning and resourcing to data analysis and improvements in subsequent cycles, which ultimately improves the quality and safety of the medical devices produced.
All news

Read also

    Companies
    Services for obtaining medical device Registration Certificates and preparing medical device documentation. We work in accordance with EAEU rules and Roszdravnadzor requirements.
    Resultat-Audit © 2026